Airon Corporation

Melbourne,  FL 
United States
http://www.aironusa.com
  • Booth: 12048


Airon pNeuton Ventilators and CPAP devices are USA made.

The pNeuton Transport Ventilator (pronounced newton) provides adult/pediatric volume targeted ventilation and high performance CPAP for use in Hospital, MRI and EMS environments.  Fully pneumatic technology eliminates the need for batteries.  A choice of 100% or 65% oxygen delivery lets you extend transport times. See the rugged versatility that makes pNeuton your future choice in transport ventilation.

Brands: pNeuton Ventilator CPAP Hospital MRI EMS Transport Pneumatic


 Products

  • pNeuton model S Ventilator with CPAP
    pNeuton model S ventilator provides mask CPAP plus volume or pressure ventilation for pediatric to adult patients for pre-hospital and hospital environments; with simple-to-use controls – Tidal Volume, Respiratory Rate and Pressure Limit....

  • Benefits for the Patient

    • Provides invasive or non-invasive patient support
    • Low patient Work of Breathing with peak flow of up to 140 L/min to meet patient needs
    • 100% or 65% to match patient oxygen requirements
    • Switch from mask CPAP to invasive ventilation seamlessly and without interruption
    • Low-profile, easy-seal mask reduces facial pressure

    Benefits for the Healthcare Provider

    • Calibrated CPAP and oxygen controls for easy operation
    • MRI conditional up to 3 T – place right next to the scanner with remote alarm output for the control room
    • Manometer to monitor patient pressure and effort
    • Built-in CPAP / PEEP system with automatic sensitivity for changing patient needs; no need for external CPAP valves
    • Night visible pressure gauge for patient monitoring
    • Monitor CO2 with invasive/non-invasive ventilation
    • Oxygen powered – no batteries to change
    • Rugged and lightweight (6 lbs / 2.7 kg)
    • Use the bacteria / viral filter to protect caregiver from patient exhalation

    Benefits for Your Budget

    • Two oxygen levels; conserve oxygen with 65% setting
    • 45-minute CPAP run time on a D cylinder
    • Demand flow CPAP system with minimal wasted oxygen
    • Economical patient circuits save on operating costs
    • No batteries or electronics decrease maintenance cost

Send Email

Type your information and click "Send Email" to send an email to this exhibitor. To return to the previous screen without saving, click "Reset".


For questions regarding the conference program, please contact

Sara Jones
Conference Coordinator
Direct: 918-831-9738
Sara.Jones@clarionevents.com

This site is best viewed in:

Chrome - 55.0 and higher
IE - 10.0 or higher
Firefox - 50.00 and higher
Safari - 5.0 and higher

For Technical Support with this webpage, please contact support.